Hyundai Firefighters Lift – Emergency Responder Elevators.
Supplied to EN 81-72 with protected controls, signalling, and dedicated power—designed for emergency operations.
Standard Speed
1.0 – 4.0 m/s
Rated Load
630 kg – 1600 kg
Water Ingress
IPX3 Electrical Protection
Safety Architecture
Emergency responder specifications
EN 81-72 Standard
Full compliance with European safety standards for firefighter rescue lifts.
Dual Power Supply
Automatic changeover to secondary emergency power lines during grid failure.
Protected Intercom
Dedicated two-way communication system direct to the designated landing station.
Protected Controls
IPX3 water-resistant electrical modules with insulated firefighter control keys.
Firefighting elevator specifications
Review core engineering parameters, compliance benchmarks, and power provisions for emergency high-rise applications.
Specification overview
Standard parameters configured to European EN 81-72 building safety codes.
| Specification | Standard & Value | Engineering details |
|---|---|---|
Compliance | EN 81-72:2020 | Firefighters lifts safety rules & water protection standards |
Controls | Protected & redundant | Dual-circuit electrical architecture with IPX3 water ingress rating |
Signalling | Dedicated firefighter control | Priority recall key switch, voice intercom & car positioning lights |
Power | Dedicated dual supply | Automatic changeover to auxiliary generator within 60 seconds |
Capacity | 1,150 – 2,000 kg | Minimum 15 to 26 passenger cabin sizing with stretcher clearance |
Application | High-rise buildings & evacuation routes | Designed for rapid deployment and continuous emergency operations |
Firefighter lifts as critical safety infrastructure
Unlike standard passenger elevators that park during an emergency, firefighter lifts remain operational under direct fire service command to move personnel and equipment swiftly to tactical staging floors.
Shaft water drainage, secondary emergency feeder lines, lobby pressurization, and hatch access clearances must be incorporated into structural and MEP drawings prior to concrete pouring.
Engineered hardware
Specialized features built for demanding installations
Every component is specified to withstand continuous heavy traffic, harsh environmental factors, and unexpected power outages.
Stainless steel cabin
Heavy-gauge brushed stainless steel walls, doors, and reinforced flooring built to resist heavy wear and corrosion.
Protected controls
Key-switch access lockouts, sealed call buttons, and tamper-resistant operating panels for secure facility management.
Redundant systems
Dual-circuit safety braking, multi-rope distribution, and independent overspeed governors for continuous safe travel.
Emergency power integration
Automatic rescue devices that direct the cabin to the nearest floor and open doors smoothly during city grid power cuts.
Need custom technical specifications?
Our engineering team in Fanar assists with shaft dimensions, load calculations, and tender submittals.
Ready to specify your firefighters lift?
For compliance documentation, control specifications, and integration details, submit the form below.